Estimation of Neutron Dose in Rems

PN

Membre a labase

Prem Narain Maheshwari

Résumé du colloque

A simple activation method was used to estimate neutron dose of different energies from a fission assembly. Surface dose from the detector was correlated with the biological dose using a conversion factor which was calculated from Snyder's graphs. This method can also be used for rapid estimation of neutron dose in case of radiation accidents or planned medical dose from a neutron source.